weber.floor 4885
Conductive, fiber-reinforced and universal wet-set adhesive for textile and elastic floorings
Colour:
light grey
Storage:
The product can be stored at least 12 months in its original unopened packaging, if kept dry, protected from humidity, and at temperatures between +5 °C and +30 °C.
Fields of application
weber.floor 4885 For gluing conductive textile floorings (tufting fabric with synthetic double backside, needle fleece), conductive homogeneous/heterogeneous PVC floorings in sheets and tiles and conductive elastomer floorings with polished backside in sheets and tiles. A conductive installation is possible with the 2 other system products: the conductive dispersion primer weber.floor 4706 and the copper conductive strip weber.floor 4918. For use indoors.
Main features
- EMICODE EC 1 PLUS: very low emission of volatile substances
- with official approval Z-155.20-545 (Germany)
- GISCODE D 1: solvent-free
- electrical leakage resistance of < 3 x 105 Ohm
- quick initial grab
- very versatile
- suitable for shampooing according to RAL 991 A2
- suitable on heated floor constructions
- suitable under chair castors according to DIN EN 12 529
General notes
- Comply with the prevailing standards and/or national guidelines relating to laying works of conductive floorings. If not issued, and if necessary, request technical advice.
- Relative humidity rate during application and drying: 40 - 65 %; max. 75%
- Adapt adhesive and flooring to room climate before application; the flooring must be free from tension.
- Observe the technical data sheets of the flooring and all other used products.
- The flash-off, open and setting times depend on the temperature (room air and substrate), relative humidity rate, substrate porosity, type of flooring and adhesive amount.
- The adhesive is sensitive to frost.
- Close opened packagings tightly and use their content quickly.
Special notes
- Neither install, nor move heavy furniture or objects on the new flooring, as long as the adhesive has not fully set.
- Avoid high temperatures caused by solar radiation.
- The substrate temperature during application and drying of elastomeric floorings should be at least +18 °C.
- If a conductive system is installed, it must be earthed by a professional electrician in accordance with prevailing regulations. The electrical conductivity is measured after complete setting of all applied products.
- The ohmic resistance of the adhesive is < 3 x 105 Ohm according to EN 13415.