weber.floor 4610
Cement-based levelling compound for industrial floors for thicknesses 4 - 15 mm (CT-C35-F10-AR0.5)
Colour:
dark grey
Water demand:
max. 5 liters/25 kg
Storage:
The product can be stored for at least 6 months in its original unopened packaging if kept dry and protected from moisture.
Fields of application
weber.floor 4610 is used for height compensation on concrete or screed industrial floors with high mechanical loads and with high demands for flatness. Dedicated for use as a wear layer on floors in warehouses and production halls with intensive forklift traffic, especially for medium or heavy loads on wheels.
Also for parking buildings and underground car parks. A subsequent application with Weber reactive-resin based coatings/paints is possible. For indoors.
Main features
- EMICODE EC 1PLUS: very low emission of volatile substances
- CE marking: CT – C35 – F10 – A0.5
- resistant to high mechanical loads
- max. grain size 1.0 mm
- suitable for mechanical application (mixing and pumping)
- very good flow performance
- early open to pedestrian traffi
- tested non-skid performance (skid-proof level 10)
- resistant to abrasion (grade AR 0.5 according to EN 13892-4 / roll test BCA)
- resistant to mineral oils
- open to water vapour
General notes
- Comply with the national standards and/or guidelines relating to levelling works of floors. If not issued and if necessary, request technical advice.
- Assess the levelling requirement beforehand and mark the finished floor heights.
- Take over existing movement joints.
- Arrange dummy joints for special structural features and special room geometry, i.e. wall entry points, doorways, wall recesses.
- High temperatures shorten, lower temperatures extend the pot life.
- During application and for at least 1 week afterwards, the substrate and ambient air temperatures should not fall below +10 °C.
- Relative humidity rate during setting: max. 70%
- In case of doubt regarding application, substrate or special structural features, request technical advice.
Special notes
- Limits of use: do not use outdoors.
- The hardened surface can vary in colour and appearance depending on raw material, job site conditions and the “handwriting” of the applicator.
- The untreated surface should generally be cleaned dry by sweeping.
- In case of chemical spillage or frequent moisture, protect the surface with a reactive resin coating.
- In case of optic demands, the layer thickness should be ≥ 6 mm. Refer to the Weber information sheet "Cleaning & care of industrial and commercial floors weber.floor 4610 - 4650".
- Do not add any foreign substances during mixing, pumping and application.